Neurodyn Esthetic


Neurodyn Esthetic Corrente Aussie, Polarizada, Micropolarizada, Microcorrente
See 3D

See picture

The equipment

Neurodyn Esthetic is a complete facial and body unit composed by the currents: Aussie, Polarized, Micropolarized and Microcurrent, as well as the techniques Aura massage and high frequency. Aura massage uses the electrostatic field naturally produced on the skin surface to carry out the electro vibration massage by oscillatory repulsion of charges.

Neurodyn Esthetic presents 4 output channels for currents, 1 channel for HF pen and 1 for Aura massage, with independent controls of intensity. It presents: 19 pre-programmed protocols and 10 private, Blue Light LCD display, soft touch keys and an exclusive arrangement of the parameters, a complete kit of accessories and an exclusive rack to support the accessories.

The equipment must be used only under prescription and supervision of a licensed professional.

 

ACCESSORIES

  • 1 power cable (Code 03017006);
  • 1 orange cable 103 – 2 wires (Code 03049027);
  • 1 black cable 104 – 2 wires (Code 03049028);
  • 1 blue cable 105 – 2 wires (Code 03049029);
  • 1 green cable 106 – 2 wires (Code 03049030);
  • 1 orange alligator clip cable 107– 2 wires (Code 03049031);
  • 1 black alligator clip cable 108– 2 wires (Code 03049032);
  • 1 blue alligator clip cable 109– 2 wires (Code 03049033);
  • 1 green alligator clip cable 110– 2 wires (Code 03049034);
  • 1 orange cable 113 for pen– 2 wires (Code 03049035);
  • 1 HF Esthetic pen (Code 02039233);
  • 1 protection fuse card (Code 03026009);
  • 1 electrolifting tip with needle for pen (Code 03025087);
  • 1 electrolifting tip for pen (Code 03025088);
  • 2 sphere tip for pen ponteiras (Code 03025086);
  • 1 hook tip for Neurodyn Esthetic pen (Code 03026052);
  • 1 roller tip for Neurodyn Esthetic pen (Code 03026051);
  • 2 Banana pen bodies 2mm (Code 03025061);
  • 1 Banana pen 4mm (Code 03025062);
  • 1 rack for Neurodyn Esthetic Accessories (Code 03038136);
  • 1 fuse 20AG of 5A (Code 03019012);
  • 8 aluminum plates 8 cm x 7cm (Code 03038171);
  • 4 black alligator clips (Code 03015066);
  • 4 red alligator clips (Code 03016067);
  • 2 facial conductive electrodes 3 x 9 x 5 x 15cm (Code 03026022);
  • 2 facial conductive electrodes 3 x 9 x 5 x 10cm (Code 03026023);
  • 8 natural sponge electrodes 9.5cm x 8.5cm (Code 03038172);
  • 4 Acupuncture needles 0.25mm x 50mm – kit with 10 needles (Code 03026002);
  • 1 gel tube – 100g (Code 03044001);
  • 1 stretch mark needle (Code 02039145);
  • 4 elastic bands for electrodes fixation (Code 03026007);
  • 1 digital Neurodyn Esthetic operation manual (Code 03040026);
  • 1 glass electrode kit for high frequency (Code 03026006);
  • 1 cable 125 for Neurodyn Esthetic Aura Massage (Code 03002003);
  • 4 green PADs with diameter of 75mm (Code 03026048);
  • 4 blue PADs with diameter of 75mm (Code 03026049);
  • 1 negative rod for Neurodyn Esthetic (Code 03025022);
  • 1 cable 82 – P/10 CH – facial pen (Code 02049077);
  • 1 electrode – Valutrode – Model VL4545 – Four/Electrode/KiT – (Code 03026031);
  • 1 electrode pente (Code 03026016);
  • 1 fork electrode (Code 03026017);
  • 1 larger sphere electrode (Code 03026018);
  • 1 smaller sphere electrode (Code 03026019);
  • 1 cauterization electrode (Code 03026020);
  • 1 saturation electrode (Code 03026021).

 

The use of cables, electrodes and other accessories different from the ones specified above may result in increase of emission or decrease in the immunity of the equipment.

 

Technical characteristics

  • Bivolt 100/240V | 50/60Hz;
  • Output channels: 4 output channels for currents, 1 channel for HF pen and 1 for Aura massage independent in amplitude;
  • Dimensions: 36 x 31.5 x 12.5 (W x D x H);
  • Approximate weight with accessories: 5.2kg.


Indications


Aussie Current

  • Strengthening, hypertrophy and muscle tonification;
  • Temporary improvement of the aspect of cellulite;
  • Improvement in lymphatic drainage;
  • Temporary improvement in body contouring;
  • Symptomatic relief of pain in plastic surgery post-operative;
  • Increase of local blood flow.

 

 

Microcurrent (MENS)

  • Improvement of skin tonus;
  • Healing improvement in acneic skin;
  • Healing improvement in the plastic surgery post-operative;
  • Tissue regeneration improvement in post-peeling;
  • Increase of local blood flow;
  • Symptomatic relief of pain in plastic surgery post-operative;
  • Increase of local blood flow;
  • Hair therapy.

 

Polarized Current (PMES)

  • Wrinkle treatment;
  • Stretch mark treatment.

 

Polarized Current

  • Oily or acneic skin treatment;
  • Increase of local blood flow;
  • Hair therapy.

 

Aura Massage

  • Symptomatic relief of pain in plastic surgery post-operative;
  • Muscle relaxation;
  • Temporary improvement of the aspect of cellulite;
  • Improvement in lymphatic drainage;
  • Temporary improvement in body contouring;
  • Increase of local blood flow.

 

High Frequency (HF)

  • Superficial disinfection of skin and scalp;
  • Increase in local blood flow;
  • In podology as an adjuvant in the treatment of onychomycosis.

Contraindications


General

  • Cardiopathy;
  • Implanted electronic device (e.g. cardiac pacemaker, deep brain stimulation device, etc.);
  • Hearing aid devices must be removed during the session. If subjected to electrical stimulation, the hearing aid devices may suffer damage and present irregularities in functioning;
  • Over or next to cancerous lesions;
  • Hypertension and unbalanced diabetes;
  • Allergy to the current;
  • Infectious processes;
  • Epilepsy;
  • Kidney and cardiac insufficiency;
  • Patients with diagnosed deep venous thrombosis (DVT).

 

Particularities for each therapeutic current:

Polarized

  • Internal or external metallic components;
  • Continuity solution.

 

Polarized Microcurrent

  • Hemophilia;
  • Vitiligo;
  • Keloid or tendency of keloid formation;
  • Protein deficiency anemia;
  • Continuity solution;
  • Use of anti-inflammatory drugs or corticoids.

 

Aussie Current

  • Muscle lesions, tendinitis and tenosynovitis;
  • Acute muscle affections, myositis, dystrophies, myopathies;
  • Non-consolidated tissues, fractures, tendon ruptures, muscles and ligaments;
  • Spasticity.

 

High Frequency

 

  • Do not use inflammable products or products of alcoholic nature as adjuvants;
  • Remove all metallic accessories from the patient;
  • This device must not be used for relief of local symptomatic pain without known etiology, unless a pain syndrome is diagnosed;
  • Over the nerves of the carotid sheath, particularly in patients with altered sensitivity to the reflexes of the carotid sheath;
  • Over the carotid area or the mouth. Muscle spasms of the larynx and pharynx may occur and the contractions may promote the closing of the upper airways, causing respiratory difficulties;
  • Over the cardiac area, for it may cause cardiac arrhythmia;
  • Over the skull cap;
  • Over infection or inflammation areas, or skin eruptions such as phlebitis, thrombophlebitis, etc.;
  • Over large caliber varicose veins, due to the risk of displacement of the thrombus.

Comparative


Estimulador Neuromuscular Neurodyn Estimulador Neuromuscular Neurodyn IIEstimulador Neuromuscular Neurodyn III
Estimulador Neuromuscular Neurodyn Compact Estimulador Neuromuscular Neurodyn Aussie Sport 
NeurodynNeurodyn IINeurodyn IIINeurodyn compactNeurodyn Aussie SportNeurodyn Evolution
Estimulador NeuromuscularEstimulador NeuromuscularEstimulador NeuromuscularEstimulador NeuromuscularEstimulador NeuromuscularEstimulador Neuromuscular
(tratamento de distúrbio uro-genecológicos e colo-proctológivos)
4 canais de saída com controles independentes4 canais de saída com controles independentes2 canais de saída com controles independentes2 canais de saída com controles independentes4 canais de saída com controles independentes3 sondas para eletroestimulação
2 sondas para biofeedback
Corrente Aussie
Corrente Russa
Corrente TENS
Corrente FES
Corrente Interferencial Tetrapolar
Corrente Interferencial Bipolar
TENS
FES
Corrente Russa
TENS
FES
TENS
FES
Corrente Russa
Corrente Aussie
(1KHz e 4 KHz)
FES
2 canais com controles: independentes
Microcorrente
Corrente Polarizada
Corrente Pulsada de Alta Voltagem
54 protocolos pré-programados e
20 particulares
32 protocolos pré-programados e
20 particulares
25 protocolos pré-programados e
10 particulares
32 protocolos pré-programados e
20 particulares
7 protocolos pré-programados e
10 particulares
Apresenta software que possibilita a criação de protocolos de tratamentos
Display LCD Blue Light teclas soft touchDisplay gráfico maior que facilita a identificação dos protocolos e programaçõesEstímulo manual através da exclusiva tecla MS.
Display Blue Ligh com teclas soft touch.
DISPLAY GRÁFICO QUE FACILITA A IDENTIFICAÇÃO DOS PROTOCOLOS E PROGRAMAÇÕESDisplay LCD blue lignt maior, teclas soft touch e disposição dos parâmetros de forma diferenciadaPode ser operado conectado ou não a um computador
ReabilitaçãoReabilitaçãoReabilitaçãoReabilitaçãoReabilitaçãoReabilitação

 

  Estimulador Neuromuscular Neurodyn Portable TENSEstimulador Neuromuscular Neurodyn Portable TENS FES  Estimulador Neuromuscular Neurodyn 10 Canais Estimulador Neuromuscular Neurodyn High Volt Estimulador Neuromuscular Neurodyn Esthetic
NeurovectorNeurodyn Portable TENSNeurodyn Portable TENS/ FESNeurodyn 10 CanaisNeurodyn High VoltNeurodyn Esthetic
Modo de estimulação interferencialEstimulador NeuromuscularEstimulador NeuromuscularEstimulador NeuromuscularEstimulador NeuromuscularEstimulador Neuromuscular
Bipolar
Tetrapolar
2 canais de saída com controles independentes2 canais de saída com controles independentes10 canais de saída com controles independentes2 canais de saída com controles independentes5 canais de saída com controles independentes
Frequência portadora
(2000 Hz, 4000 Hz ou 8000 Hz)
TENSTENS
FES
Corrente Russa
(2.500Hz)
Eletrolipólise e Corrente Aussie
(1.000 e 4.000 Hz)
CPAV
Eletroporação
Corrente Aussie
Microcorrente Polarizada (PMES)
Corrente Polarizada (POL)
Microcorrente (MENS)
Massagem Aura
modos
contínuo, sincrônico, recíproco, desobstrução e sequencial
sexto canal com controle independente de intensidade para Alta Frequência
20 protocolos pré-programados e
10 particulares
12 protocolos pré-programados e
20 particulares
19 protocolos pré-programados e
10 particulares
Equipamento portátil que pode ser operado com bateria de 9 volts ou conectado à rede elétricaEquipamento portátil que pode ser operado com bateria de 9 volts ou conectado à rede elétricaTeclas soft touch. Design diferenciado, com cabos coloridosDisplay gráfico maior que facilita a identificação dos protocolos e programaçõesDisplay LCD blue light, teclas soft touch e disposição de parâmetros de forma diferenciadas.
ReabilitaçãoReabilitaçãoReabilitaçãoReabilitação e estéticaReabilitação e estéticaestética

Ibramed 2018 © | All rights reserved

O número de atendimento da
IBRAMED mudou

Para falar conosco, é só mandar uma mensagem de WhatsApp para o número (19) 3817-9633 ou clicar no link ao lado para ser redirecionado(a).