Sonopulse II



See 3D

See picture

The equipment

Microcontrolled equipment that has therapeutic ultrasound therapies at frequencies of 1.0 MHz and 3.0 MHz in addition to electrostimulation, with Russian, Interferential, Polarized and High Volt (or High Voltage) currents. Combination therapy can be performed by combining therapeutic ultrasound with electrostimulation. Sonopulse II can be used in the area of ​​aesthetics and rehabilitation.

The equipment has the following operating possibilities:

1.0 MHz and 3.0 MHz ultrasound therapy whose emission can be continuous or pulsed at the frequencies of 100Hz, 48Hz or 16Hz and 50% or 20% duty cycle, maximum power of 20 Watts, ERA radiation) of 10 cm² and maximum intensity of 2 W / cm².
Isolated therapy, being any type of electrostimulation current present in the equipment.
Combination therapy which is the association of the ultrasonic wave associated with Russian, Interferential, Polarized or High Voltage current.

It has 4 output channels, 2 for electrostimulation with Russian, Interferential and Polarized current, 1 channel where the ultrasonic transducer is connected and 1 output channel for High Volt current. It has 59 preprogrammed protocols and 10 private protocols.

The equipment must be operated by qualified professionals and within licensed medical departments.

ACCESSORIES

01 Female IEC PP Cable – 2 x 0.75 x 1500mm
01 Cable 99 – Sonopulse II – Terap. Combined – HV
01 Cable Kit 92 – Sonopulse II – Pins – Orange
01 Cable Kit 93 – Sonopulse II – Pins – Black
01 Cable Kit 94 – Sonopulse II – Claws – Orange
01 Cable Kit 95 – Sonopulse II – Claws – Black
01 Cable Kit 96 – Sonopulse II – HV – Yellow / Black
01 Cable Kit 97 – Sonopulse II – Terap. Combined – Galvanica
01 Cable Kit 98 – Sonopulse II – Terap. Combined – Russian / Int.
02 Pad Green Diameter 75mm
02 Pad Blue Diameter 75mm
04 Vegetable Cloth Electrode 12cm x 10cm
04 Aluminum Plate
01 Self Adhesive Electrode Valu Trode Size 8x13cm.
01 Tube with Gel (Cap. 100 grams)
01 IBRAMED 260410 Digital Operation Manual
01 Protection Fuse Card diamond line
01 Fuse 20 Ag 5A
01 Silicone Headset Kit w / NTC 10CM2 – UNI

TECHNICAL CHARACTERISTICS

Automatic dual voltage: 100 to 240 V | 50/60 Hz.

Ultrasound: frequency of 1.0 MHz (± 5%) / 3.0 MHz (± 5%) / Effective Area of ​​Ultrasonic Radiation (ERA): 10 cm² / Maximum Effective Power: 20 Watts / Maximum Effective Intensity: 2 W / cm² / Modes: continuous or pulsed.

Russian Current: carrier frequency of 2500Hz, R = 50Hz and T: 50% being from 1 to 120 mA (peak to peak).

Interferential Current: Average carrier frequency of 2,000 Hz, 4,000 Hz or 8,000 Hz, Carrier: 4KHz and AMF: 100Hz being 1 to 120 mA (peak to peak).

Polarized Current: average carrier frequency of 15000Hz, ranging from 1 to 30 mA (peak).

High Volt Current: (R = 250 Hz): 1 to 250 volts (peak to peak).

DIMENSIONS

Width: 375mm
Depth: 315mm
Height: 125mm
Approximate weight without accessories: 2.4 kg



Treatments


U.S. + Corrente Russa

U.S. + Russian Chain

U.S. + Corrente Polarizada

U.S. + Polarized Current

U.S. + Corrente High Volt

U.S. + High Volt Current

Corrente Russa

Russian chain

Corrente Interferencial

Interferential Current

Corrente Polarizada

Polarized current

Corrente High Volt

High Volt Current

Ultrassom Terapêutico (U.S.)

Therapeutic Ultrasound (U.S.)

Indications


Therapeutic Ultrasound: In Rehabilitation: arthrosis (large and small joints), bursitis, analgesia, lameness, neuritis, neuralgias, periarthritis, Raynaud’s disease, myalgia, various rheumatisms, myositis, ulcers, venous stasis, Sudeck’s atrophy, bursitis, edema, acute and chronic pain diagnosed, radiculitis, escalene syndrome, early and late postoperative, scars and tissue retractions and ligament, muscle and tendon injuries in the acute and chronic phase. In Aesthetics: localized fat, cellulitis, immediate and late postoperative, adhesions and scarring fibroses, edema drainage, analgesia, hematoma drainage and hydrolipoclasia.

Russian Current: It is indicated for motor stimulation promoting muscle strengthening, hypertrophy and toning, being used in physical rehabilitation and aesthetics.

Interferential Current: In Physical Rehabilitation: is indicated in cases of drainage of edema, analgesia, increased metabolism and local vascularization. In Aesthetics: can be used for analgesia in cases of P.O. and lymphatic drainage. Synchronized or reciprocal bipolar mode allows motor stimulation for muscle strengthening and toning.

Polarized Current: Used to permeate active or defined polarity drugs.

High Volt Current: It is indicated for pain modulation, healing of skin ulcers, edema drainage, trauma recovery and muscle rehabilitation.

GENERAL INDICATIONS:

In Physical Rehabilitation:

Inflammatory rheumatic disorders
Inflammatory disorders of the peripheral nervous system
Traumatic disorders
Peripheral Circulatory Disorders
Inflammatory disorders of superficial areas of the skin
Tissue healing
Drainage of edema
Analgesia
Muscle strengthening and toning
Degenerative changes of the skeleton mainly of the spine
Periarthritis
Cellulite
Phonophoresis
Post Surgical

In Aesthetics:

Cellulitis
Localized fat
Muscle sagging
Lymphatic drainage
Analgesia
Immediate and late postoperative
Hematoma Drainage
Muscle toning
Ionization

Contraindications


Therapeutic Ultrasound:

Gravity of the uterus, eyeball, areas of thrombophlebitis, acute vascular pathologies, heart, implanted electronic device, metallic implants, neurovegetative system, brain, reproductive organs, acute infections, radiotherapy-treated areas, tumors, and sites with sensory changes.

Chains:

Pregnant or intending to become pregnant, heart disease, implanting electronic device, hearing aids, local tumor, decompensated hypertension and diabetes, allergic reactions due to use of electrostimulation, infectious processes and epilepsy.

Comparative


SONOPULSESONOPULSE IISONOPULSE IIISONOPULSE 1 MHz
ULTRASSOM
1MHz e 3MHz
ULTRASSOM 1MHz e 3MHz
CORRENTE RUSSA , ALTA VOLTAGEM, INTERFERENCIAL E POLARIZADA
ULTRASSOM
1MHz e 3MHz
ULTRASSOM
1MHz
ERA
7cm2 (1MHz e 3MHz)
(potência máxima de 21W)
3cm2 (1MHz)
(potência máxima de 3W)
ERA
10cm2
(potência máxima 20W)
ERA
7cm2
(potência máxima 21W)
ERA
7cm2
(potência máxima 21W)
PERMITE TERAPIA COMBINADAENTRADA PARA TERAPIA COMBINADAENTRADA PARA TERAPIA COMBINADA
46 protocolos pré-programados e
20 particulares
59 protocolos pré-programados e
10 particulares
46 protocolos pré-programados e
20 particulares
26 protocolos pré-programados e
20 particulares
Maior display gráficoDISPLAY GRÁFICO E TECLAS SOFT TOUCHDISPLAY GRÁFICO QUE FACILITA A IDENTIFICAÇÃO DOS PROTOCOLOS E PROGRAMAÇÕESDISPLAY GRÁFICO QUE FACILITA A IDENTIFICAÇÃO DOS PROTOCOLOS E PROGRAMAÇÕES
Reabilitação e estéticaReabilitação e estéticaReabilitação e estéticaReabilitação

Ibramed 2018 © | All rights reserved