Striat


Striat Equipamento Eletroestimulador Transcutâneo e Percutâneo
See 3D

See picture

The equipment

Striat is a transcutaneous and percutaneous electrostimulator designed for use in esthetics treatments, which presents a stimulation channel with continuous Microgalvanic electric current (GMES, that is, galvanic current in microampères), and can be used for the electrolifting with or without needle.

It is composed of intensity of current of up to 990 microampères and allows the adjustment of application time. The equipment also presents a Blue Light LCD display, soft touch keys, a light and anatomical pen for carrying out the technique and a transport bag.

The equipment must be used only under the prescription and supervision of a licensed professional.

 

Accessories

  • 1 power supply cable;
  • 1 vegetable fiber textile electrode 9.5 x 8.5mm;
  • 1 orange kit cable 103 (2 wires) for Esthetic Aussie injected;
  • 1 electrolifting tip with needle;
  • 1 electrolifting tip with needle;
  • 1 Banana pen body 2mm;
  • 1 black alligator clip;
  • 1 aluminum plate 8cm x 7cm;
  • 1 digital Striat Inmetro operation manual;
  • 1 elastic band for electrode fixation;
  • 1 kit of needles;
  • 1 case.

 

The use of cables, electrodes and other accessories different from those specified above may result in increase of emissions or decrease of the immunity of the equipment. The device and its characteristics may suffer alterations without previous notice.

 

Technical characteristics

  • Bivolt 100/240V | 50/60Hz;
  • 1 output channel;
  • Dimensions: 15 x 18.5 x 9.5 WL x D x H cm);
  • Approximate weight without accessories: 0.8kg.


Indications


  • Increase of local blood flow;
  • Electrolifting;
  • Wrinkles;
  • Stretch marks;
  • Expression lines;
  • Atrophic scars.

Contraindications


General:

  • Cardiopathy;
  • Implanted electronic device (ex.: cardiac pacemaker, deep brain stimulation device, etc.);
  • Hearing aids must be removed during the session. If exposed to electrical stimulation, the hearing aid devices may suffer damage and present functioning irregularities;
  • Tumor in the area;
  • Hypertension and unbalanced diabetes;
  • Allergy to the current;
  • Infectious Processes;
  • Epilepsy;
  • Kidney and cardiac insufficiency;
  • Patients with diagnosis of Deep Venous Thrombosis.

 

Microgalvanic:

  • Hemophilia;
  • Vitiligo;
  • Keloids or propension keloids;
  • Protein deficiency anemia;
  • Continuity solution;
  • Systemic use of anti-inflammatory or corticoid medication.