Heccus Turbo

Heccus Turbo

Innovative combined therapy platform

The equipment Heccus Turbo is an innovative platform of combined therapies for body aesthetic treatments, with therapeutic modalities of high power ultrasound with flat transducer, Aussie Current, Polarized Current and High Volt Current.

The biggest power on the market

72 watts

The Heccus Turbo features ultrasonic energy delivered in a three-dimensional form with the highest power on the market, with 72 Watts, and the largest effective radiation area of 24 cm².

Exclusive Aussie Current

The Aussie current is the evolution of therapeutic currents, being exclusive to Ibramed and indicated for several treatments with the objective of muscle strengthening, analgesia and lymphatic drainage.

8 CHANNELS

of chains

The Heccus Turbo features 8 output channels for Aussie current, and 2 channels for polarized and High Volt currents;

Exclusive mode

super pulsed

For greater efficiency, the Heccus Turbo features 75% super pulsed mode, to deliver the ultrasound energy in a fractional way, yet generating the heat necessary to obtain the results.

Technology

Duet System

It features Duet System technology, which allows different treatments in more than one body region at the same time, reducing treatment session time and optimizing results.

Applicator

two in one

Ultrasound allows automatic adjustment of 1.1 MHz and 3.3 MHz frequencies in the same applicator, without the need to change the transducer for therapy.

Optimization

treatment

It has protocols that direct the treatment according to the indications of use and the therapeutic objective, therefore, the system directs to the appropriate treatment modality.

Exclusive

technique

The only one on the market with anodized crystals that lead to greater effectiveness of electrical currents in the treatment area, in addition to allowing the unique electrodynamic technique of the transducer, which is a differential for optimizing treatments with therapeutic currents in large body areas!

Indications

  • Cellulite
  • Localized fat
  • Sagging skin
  • Postoperative after plastic surgery
  • Muscle flaccidity
  • Lymphatic Drainage
  • Body modeling

Device information

Accessories

  • 1 I.E.C female PP cable 3 x 0.75 x 1500mm (Code 03017007);
  • 1 orange and black cable 72 – 10 cH for Aussie and Russian currents (Code 03049010);
  • 1 blue and green cable 73 – 10 cH for Aussie and Russian currents (Code 03049011);
  • 1 gray and pink cable 74 – 10 cH for Aussie and Russian currents (Code 03049012);
  • 1 white and yellow cable 74 – 10 cH for Aussie and Russian currents (Code 03049013);
  • 1 yellow dispersive cable (Code 03049068);
  • 1 High Volt cable (Code 03049067);
  • 8 red alligator clips (Code 03015067);
  • 8 black alligator clips (Code 03015066);
  • 4 aluminum plates measuring 8 x 7 cm (Code 03038171);
  • 4 natural sponge electrodes measuring 9.5 x 8.5 cm (Code 03038172);
  • 1 aluminum plate 7.5 x 14cm (Code 03026075);
  • 1 natural sponge electrode 8 x 15cm (Code 03026074);
  • 16 8 x 7.5 cm black conductive electrodes (Code 03026180);
  • 1 digital operations manual (Code 03040024);
  • 1 tube with 100g gel – ANVISA registration No. 80122200001 – manufacturer: RMC – IND. BRASILEIRA DE PRODUTOS MÉDICOS LTDA. (Code 03044001);
  • 4 acupuncture needles 0.25 x 50mm (pack of 10 needles) – ANVISA registration n° 10390380001 – manufacturer: DONG BANG ACUPUNTURE, INC. – distributor: XU LI COMÉRCIO IMPORTAÇÃO E EXPORTAÇÃO LTDA. (Code 03026002);
  • 1 fuse 20AG – 05A (Code 03019012);
  • 1 mega gel – ANVISA registration 80122200006 – manufacturer: RMC – IND. BRASILEIRA DE PRODUTOS MÉDICOS LTDA. (Code 03044010);
  • 1 adipometer (Code 03026098);
  • 1 bucket (Code 03026095);
  • 1 spatula (Code 03026096);
  • 1 sprayer (Code 03026108);
  • 1 measuring tape (Code 03026099);
  • 8 elastic straps for electrode fixation (Code 03026007);
  • 1 remote control (Code 03026091);
  • 1 face towel (Code 03026057);
  • 1 body towel (Code 03026058);
  • 1 body tonic 120ml – ANVISA registration No. 343/05 – manufacturer: SKINHAIR IND. AND WITH. COSMETICS LTD. (Code 03044013).
Technical Features

  • Automatic bivolt: 100 to 240 V | 50/60 Hz;
  • Ultrasound: frequency of 1.1 MHz (±10%) / 3.3 MHz (±10%) / Effective Radiation Area (ERA): 24cm² / Maximum output power: 72W (± 20%) / Modes: continuous or pulsed;
  • Aussie current: 1 or 4 kHz (± 10%) / Burst duration: 2 or 4ms (± 10%) / burst frequency: 01-120 Hz (± 10%);
  • Polarized current: 15KHz frequency (± 10%) / Polarity: positive or negative;
  • High Volt Current: 1-300 V peak output intensity / Polarity: positive or negative / Frequency: 1-250 Hz.
Application Techniques

Heccus Turbo has optimized protocols and is easy to operate. Simply select the therapeutic objective, and the system directs you to the appropriate treatment modality.

High Power Ultrasound

Ultrasound at frequencies of 3.3MHz and 1.1MHz, which allows efficient treatment even in thicker adipose tissue. It has 3 ultrasound emitters with ERA – effective radiation area – of 8cm² (totaling 24cm²), with 24W each and maximum output power of 72W, promoting greater therapeutic effect and shorter session time.

The Heccus Turbo also features continuous, pulsed and superpulsed modes, in addition to a light and ergonomic transducer. And it associates thermal and mechanical effects, which produce vasodilation and increase in tissue viscoelasticity, cavitation, signal mechanotransduction, lipolysis, angiogenesis, thixotropic effect, among others. In this modality, only the ultrasound transducer and gel with or without actives are used.

Aussie current

Aussie is a burst modulated medium frequency alternating therapeutic current. It offers two frequency possibilities: 1KHz and 4KHz, which allows selection of the frequency according to the therapeutic objective, with 1KHz for muscle strengthening and toning, while the frequency of 4KHz for lymphatic drainage and analgesia.

The Aussie current features continuous, synchronous, sequential and reciprocal output modes, in addition to a short duration burst (2ms in 1KHz current and 4ms in 4KHz current), which makes the stimulation provided more efficient compared to other therapeutic electrical currents.

In this modality, the Heccus Turbo allows static technique with electrodes (8 output channels) or dynamic technique (via transducer), depending on the treatment protocol chosen.

Polarized Current

Polarized is a single-phase pulsed current that flows in only one direction. Its therapeutic application is intended for dynamic and static iontophoresis (permeation of assets through electrorepulsion) associated with the polar effects of current. The current contemplates positive and negative mode.

In this modality, Heccus Turbo allows static technique with electrodes (2 output channels) or dynamic technique (via transducer and dispersive electrode), depending on the treatment protocol chosen.

High Volt Current

High Volt current, also known as high-voltage pulsed current (CPAV), or high-voltage electrical stimulation (HEAV), is a current with twin pulses of high amplitude and short duration. Its waveform is single-phase (current flows in only one direction). The high voltage causes a decrease in skin resistance, making the current comfortable and tolerable. It offers both continuous and synchronous output modes.

In this modality, the Heccus Turbo allows static technique with electrodes (2 output channels) or dynamic technique (via transducer and dispersive electrode), depending on the treatment protocol chosen.

Three-dimensional sonophoresis

This therapeutic modality combines high power ultrasound with Aussie current in the same therapy time.

When selecting the desired protocol, simply select the value corresponding to the number of applicators that fit in the region to be treated and the calculation of the treatment time is automatically given by the equipment. To calculate the ultrasound intensity, simply measure the fat layer using an adipometer and enter the value in centimeters on the screen. The adjustment of ultrasound intensity and ultrasound mode (continuous or pulsed) is automatic.

In this mode, only the transducer and neutral or active conductive gel are used.

Sonoiontophoresis

This therapeutic modality associates high power ultrasound with polarized current in the same therapy time.

When selecting the desired protocol, simply select the value corresponding to the number of applicators that fit in the region to be treated and the calculation of the treatment time is automatically given by the equipment. To calculate the ultrasound intensity, simply measure the fat layer using an adipometer and enter the value in centimeters on the screen. The adjustment of ultrasound intensity and ultrasound mode (continuous or pulsed) is automatic. The product polarity must also be set to P+ or P-.

In this mode, the transducer, conductive gel with actives of defined polarity, yellow dispersive cable, aluminum plate electrode with vegetable cloth and alligator clip adapter are used.

Sonoelectroporation

This therapeutic modality associates high power ultrasound with High Volt current in the same therapy time.

When selecting the desired protocol, simply select the value corresponding to the number of applicators that fit in the region to be treated and the calculation of the treatment time is automatically given by the equipment. To calculate the ultrasound intensity, simply measure the fat layer using an adipometer and enter the value in centimeters on the screen. The adjustment of ultrasound intensity and ultrasound mode (continuous or pulsed) is automatic.

In this mode, the transducer, conductive gel with actives, yellow dispersive cable, aluminum plate electrode with vegetable cloth and alligator clip adapter are used.

The application of treatments should only be done by qualified and duly qualified professionals.

Indications

Individual therapies

Therapeutic ultrasound

  • Improved healing after plastic or reconstructive surgery;
  • Localized fat reduction;
  • Cellulite;
  • Improves the quality and firmness of the skin;
  • Hydrolipoclasia.

Aussie current

  • Strengthening, hypertrophy and muscle toning;
  • Increased local blood circulation;
  • Relief of pain after plastic or reconstructive surgery;
  • Increased lymphatic and vascular drainage;
  • Cellulite;
  • Localized fat reduction (electrolipolysis).

Polarized Current

  • Asset permeation (iontophoresis);
  • Increased local circulation.

High Volt Current

  • Asset permeation (electroporation);
  • Healing of ulcers and wounds;
  • Increased local blood circulation;
  • Relief of pain after plastic or reconstructive surgery;
  • Increased lymphatic and vascular drainage.

Combination therapies

Three-dimensional sonophoresis (therapeutic ultrasound + Aussie current)

  • Localized fat associated with muscle toning;
  • Localized fat associated with lymphatic drainage;
  • Gynoid lipodystrophy (cellulitis) associated with muscle toning;
  • Gynoid lipodystrophy (cellulitis) associated with lymphatic drainage;
  • Improvement of scarring associated with analgesia in the postoperative period of plastic or reconstructive surgery;
  • Improves the quality and firmness of the skin.

Sonoelectroporation (therapeutic ultrasound + High Volt current)

  • Localized fat associated with electroporation of assets;
  • Gynoid lipodystrophy (cellulite) associated with electroporation of assets;
  • Improved healing associated with analgesia in the postoperative period of plastic or reconstructive surgery.

Sonoiontophoresis (therapeutic ultrasound + polarized current)

  • Localized fat associated with active ionization;
  • Cellulite associated with active ionization.
Contraindications

For therapeutic currents

  • Pregnant women or intending to become pregnant;
  • Cardiopathy;
  • Implanted electronic device (eg, cardiac pacemaker, deep brain stimulation device, etc.);
  • Hearing aids must be removed during the session. If subjected to electrical stimulation, hearing aids can be damaged and malfunction;
  • Tumor in place;
  • Decompensated hypertension and diabetes;
  • Allergic reactions resulting from the use of electrostimulation;
  • Infectious processes;
  • Epilepsy.

For therapeutic ultrasound

  • Pregnant women or intending to become pregnant;
  • Patients with bleeding diathesis or bleeding disorders;
  • Not to be used for the relief of symptomatic local pain of no known etiology unless a pain syndrome is diagnosed;
  • Neoplastic areas or over areas where the tumor has been removed;
  • About the eyes;
  • About bony epiphyses still growing;
  • Patient with implanted electronic device;
  • About areas previously treated with radiotherapy;
  • About the gonads to prevent heating;
  • About the cardiac area;
  • About areas of thrombophlebitis, deep vein thrombosis, emboli, and severe atherosclerosis;
  • About ischemic areas;
  • Suspected infectious disease;
  • Over the stellate ganglion, spinal cord, and over the skull;
  • Areas of reduced sensitivity or circulation or over anesthetic areas.
Frequently asked questions

What are the power modes of the Heccus Turbo?

The Heccus Turbo allows multiple therapy combinations: three-dimensional sonophoresis (ultrasound + Aussie current), sonoelectroporation (ultrasound + High Volt current) and sonoiontophoresis (ultrasound + polarized current).

Is it possible to achieve results even in patients with greater thickness of adipose tissue?

The Heccus Turbo brings ultrasound at frequencies of 3.3MHz and 1.1MHz, which is directly related to the depth of action. As the adipose tissue thickness is adjusted in the “Adipometer” parameter on the screen, Heccus Turbo automatically selects the best treatment frequency for the therapeutic objective.

What is the effect of the superpulsed mode in the treatment of localized fat?

The superpulsed mode combines the effects of cavitation with the heat of high power and the effect of acoustic shock waves. This sum favors the emulsification of fats in the adipocyte, inducing apoptosis and making the treatment more efficient.

How is it possible to calculate the session time through the transducer?

Just as the conventional Heccus uses the time calculation by measuring the area to be treated (area in cm²/ERA), the Heccus Turbo uses the area of ​​the transducer itself to calculate the time. The application time parameter is adjusted following the calculation: measurement of the applicator area = 100cm² divided by 24 (size of the effective area of ​​ultrasound radiation), totaling 4 minutes of application per physical area of ​​the applicator.

Then, measure with the transducer itself and press the corresponding number on the screen, and the equipment will program the time. This results in less time to prepare for the session.

How do I calculate the optimal ultrasound intensity for my treatment?

To calculate the ultrasound intensity, the “Adipometer” parameter must be adjusted. With the help of an adipometer, measure your patient’s treatment area and enter the value obtained in centimeters on the “Data entry” sub-screen (maximum value = 4.5 cm). The adjustment of the ultrasound intensity and the ultrasound mode (continuous or pulsed) will be done automatically.

What do I find on the “Info” screen?

On the “Info” button, you will find an informative tutorial for each treatment protocol, images and precise information on how to use the equipment in each protocol. In addition, of course, to clear, quick and functional information for the therapist, optimizing the use of the equipment and promoting improved results.

When can I use the remote control that comes with the equipment?

The remote control is an auxiliary device that allows starting (Start) and stopping (Stop) the combined therapy and adjustment of the current intensity during the session, in the following modalities: three-dimensional sonophoresis (ultrasound + Aussie), sonoiotophoresis (ultrasound + polarized) and sonoelectroporation (ultrasound + High Volt).

What can I do to prevent the head from overheating?

During treatment, the gel tends to dehydrate, making the passage of ultrasonic energy difficult, especially in large areas and high powers. This can raise the internal temperature of the transducer. To prevent this from happening, spray water over the gel during treatment and add gel to the area being treated.

However, if the temperature reaches the safety limit (41°C), the equipment cuts off the ultrasound emission and freezes the timer. On the display, an image appears showing excess temperature and the equipment beeps during the entire time that the equipment is not emitting.

Spray water over the gel and continue with the treatment movement, this helps the temperature to drop more quickly. Only when the temperature returns below 41°C, the ultrasound is emitted again. Increase the current dose again to continue the treatment.


Where can I find this product?